Description
The MST product line provides you with full control over temperature by heating or cooling, resulting in a comfortable environment for your livestock.
The MST-5C has the same features as the MST-5 controller with the advantage of being able to connect to Farmquest.
Details
- Equipped with Core 100 technology – wireless communication antenna
- Compatible with the FarmQuest platform
- Compatible with 2 speed motors
- Hi / Lo temperature recall
- Timer on first stage non-active above the set point
- Timer for drip cool unit
- Automatic temperature ramping
- Adjustable differential for cooling and heating stages
- 2004-10k temperature probe included
Advantages
- Up to four-probe average temperature
- Stages 1-2-3 cooling
- Stages 4-5 heating / cooling
- Timer on 1 st stage for minimum ventilation, non active above set point
- Temperature ramping
- Adjustable differential for cooling and heating stages
- Mist timer incorporated to stage 3
- Hi / Lo temperature recall
- Single and 2-speed motors
- 5-digit LED display
- Most effective lightning protection
- Extended temperature range
- Extended supply voltage range
- Radio interference filter
- Alarms, Hi/Lo, loss of power & defective control
- Maintain settings after power loss
- Two-year limited warranty
MST-5C Compatible Modules
This is the list of all compatible modules that can be connected with MST-5C control with a short description of their function.
Computer interface
- NET-IN2 Communication Module (Module inserted into the controller to communicate with the computer interface)
- RF-IN Communication Module (Module inserted into the controller for a wireless communication with the computer interface)
Ventilation system overview
The MST-5C uses up to 4 inside temperature probes, an outside temperature probe and a relative humidity probe to control 5 on/off stages. Stage 1 can operate according to a timer when temperature is under its activation set point. The third on/off stage can be used as a mist stage or as a cooling stage. That stage will operate according to its timer when its activation temperature is reached and can be shutoff if relative humidity is high. The last two on/off stages can operate as heaters or cooling stages. Heaters can operate according to the sensors selected by the user.
When a temperature probe is defective (short-circuited or unplugged), the MST-5C controller will not consider that probe in the average temperature and the alarm will sound. An alarm check will be made to check for high/low temperature and defective probes. The outside temperature may increase the high alarm threshold. The alarm will also activate if the difference between any two inside probes is too great.